Heat transfer calculators
13 calculations for energy balances, heat exchangers, insulation and heating or cooling times, each with its formula and practice problems.
Energy balances
Sensible heat
No phase change. cp varies with temperature: use the value at the mean temperature. A negative result means heat removed.
Latent heat (steam, ice)
Latent heat only (saturated steam condensing to saturated condensate). Sub-cooling the condensate adds some sensible heat. Values from steam tables, rounded.
Mixing temperature of two streams
Same fluid on both sides (same cp), no phase change, no losses. Also works with masses (kg) for a batch blend in a tank.
Energy to heat a tank
Ignores tank heat losses and the vessel metal: add 10 to 30 % depending on insulation. Electric immersion heater η ≈ 100 %; gas burner 80 to 90 %.
Heat exchangers
Exchanger heat balance: outlet temperature
Assumes no losses to the surroundings. If the calculated cold outlet is above the hot inlet, the flows or temperatures are not consistent.
LMTD and required area
Valid for pure counter-current or co-current flow. For a multipass shell-and-tube unit, multiply the LMTD by the correction factor F (often 0.8 to 0.95).
Effectiveness-NTU (counter-flow exchanger)
To rate an existing exchanger when U and A are known but the outlets are not. C = ṁ × cp; when both C are equal, ε = NTU ÷ (1 + NTU).
Overall U (films and fouling)
Thin wall: inside and outside areas taken as equal. k: carbon steel ≈ 45, stainless ≈ 16, copper ≈ 385 W/m·K. Cooling-tower water Rf: 0.0002 to 0.0004 m²·K/W.
Conduction, insulation and radiation
Conduction through a flat wall (2 layers)
Set L₂ = 0 for a single layer. hₒ in still air including radiation: 8 to 12 W/m²·K; in wind: 20 to 40. k firebrick ≈ 1, mineral wool ≈ 0.04 to 0.06 W/m·K.
Heat loss from an insulated pipe
Radial conduction (Incropera); steel wall and inside film neglected (safe side). hₒ must include radiation. Surface above 60 °C: burn risk.
Radiation between surfaces
Grey bodies, σ = 5.67 × 10⁻⁸ W/m²·K⁴, temperatures converted to kelvin. ε₂ is used only for parallel plates. ε: oxidised steel ≈ 0.8, paint ≈ 0.9, polished aluminium ≈ 0.05.
Heating and cooling times
Tank cooling (Newton's law)
Well-mixed liquid (lumped model), constant UA, no draw-off or feed. To find UA, log a temperature drop over a few hours and invert the formula.
Batch heating time (steam coil)
Stirred vessel, saturated steam at constant temperature, losses neglected. Saturated steam: 1 barg ≈ 120 °C, 3 barg ≈ 144 °C, 7 barg ≈ 170 °C.
Learning and checking tools. The ranges shown are general guidance: always follow your plant's procedures, permits and set points. Nothing is sent anywhere: the calculations run in your browser.